Switching Mode Power Supply
LTE 60U SERIES 60W MULTIPLTE OUTPUT SWITCHING POWER SUPPLY

FEATURES:
  • DIMENSIONS:5”x3.2”x1.5”
  • DOUBLE SIDE PCB FOR HIGH RELIABILITY
  • BUILT-IN CLASS B EMI FILTER (AC OR DC INPUT)
  • EN61000-3-2 CLASS A (HARMONIC DISTORTION CORRECTION)
  • ADJUSTABLE MAIN OUTPUT
  • OVERLOAD PROTECTION
  • OVERVOLTAGE PROTECTION
  • SHORT CIRCUIT PROTECTION
  • DC INPUTS 48VDC FOR DC/DC TYPE (OPTIONAL
  • LOW LEAKAGE CURRENT MEDICAL MODEL (OPTIONAL)
  • CE MARKED TO LOW VOLTAGE DIRECTIVE (LVD)


APPLICATION:
  • COMPUTER PERIPHERALS/LAN & HUB
  • TEST & INDUSTRIAL EQUIPMENTS
  • MEDICAL INSTRUMENTS
ENVIRONMENTAL:
  • OPERATING TEMPERATURE:0°C TO 40°C AMBIENT, DERATED EACH OUTPUT AT 2.5% PER °C FROM 40°C TO 70°C
  • STORAGE TEMPERATURE:-40°C TO 85°C
  • HUMIDITY:OPERATING, NON-CONDENSING, 5% TO 95%
  • VIBRATION:RANDOM OPERATING 2.4 GRMS/MAX. 3 AXES 50~500Hz 10 MINUTES/AXIS
  • SHOCK:OPERATING HALF SINE 20 GPK/MAX. 3 AXES 10mS 6 SHOCKS TOTAL

INPUT SPECIFICATIONS:
VOLTAGE 90-264 VAC, Universal
FREQUENCY 47-63Hz
CURRENT 1.5ARMS. MAX. @115VAC 60w LOAD / 2ARMS. MAX. @115VAC 80w LOAD
  1ARMS. MAX. @230VAC 60w LOAD / 1.3ARMS. MAX. @230VAC 80w LOAD
INRUSH SURGE CURRENT 35A typical, Cold start @25°C, 115VAC

OUTPUT SPECIFICATIONS:
OUTPUT WATTAGE 60 Watts MAX. (CONVECTION RATING)/ 80 Watts MAX. (WITH 15CFM FORCED AIR)
VOLTAGE SEE TABLE
CURRENT SEE TABLE
LINE REGULATION +/- 1% typical
LOAD REGULATION Main outputs +/- 5%, Aux. Outputs +/- 10% typical (NOTE1)
NOISE & RIPPLE 1% typical at full load (NOTE2)
OVERSHOOT/UNDERSHOOT 10% MAX. @ TURN-ON/ TURN-OFF

GENERAL SPECIFICATIONS:
  • EFFICIENCY:>70% typical AT FULL LOAD
  • TURN-ON TIME:3SEC MAX. AT FULL LOAD @ 115VAC
  • HOLD-UP TIME:10ms typical at full load @ 115VAC
  • REMOTE SENSE:250mV +/- 50mV @ V1 AT FULL LOAD
  • MTBF DEMONSTRATED:>100,000 HOURS AT FULL LOAD AND 25°C AMBIENT CONDITIONS
ELECTROMAGNETIC COMPATIBILITY SPECIFICATIONS:
  • EMI Conducted/RADIATED:FCC & CISPR Class B
  • DESIGNED TO MEET EN61000-3-3,-4-2,-3,-4,-5,-6,-11