Switching Mode Power Supply  |
| LTE 60FS SERIES 60W SINGLE OUTPUT SWITCHING POWER |
| INPUT / OUTPUT SPECIFICATION |
- VOLTAGE: 100-240 VAC, Universal
- FREQUENCY: 47-63
- CURRENT: 1.5 ARMS. MAX @115 Vac 90W LOAD
- INRUSH SURGE CURRENT: 30A TYPICAL, COLD START@25 Degree, 115Vac
- OUTPUT WATTAGE: 26.4Watts ~65Watts MAX (Convection Rating)
- LIND REGULATION: +/- 0.5 % Typical
- LOAD REGULTION: Main Outputs +/- 5%, Aux Outputs +/- 10% Typical (Note1)
- NOISE & RIPPLE: 1 % Typical At Full Load (Note2)
- OVERLOAD / VOLTAGE PROTECTION: TYPICALLY 115~200% CONTINUOUS HICCUP MODE
|
|
|
| Note: |
1. |
LOAD REGULATION TESTED AT 0 ~100% OIF MAX LOAD |
| 2. |
PEAK-TO-PEAK FOR 26.4W~65W (CONVECTION RATING) @90VAC MIN. ; MEASUREMENTS WITH A 20MHz BANDWIDTH AND TERMINATED WITH A 10uF ELECTROLYTIC CAP. IN PARALLEL WITH A 0.1uF CERAMIC CAP. |
| ENVIRONMENTAL: |
- OPERATING TEMPERATURE:0°C TO 50°C AMBIENT, DERATED EACH OUTPUT AT 2.5% PER °C FROM 50°C TO 70°C
- STORAGE TEMPERATURE:-40°C TO 85°C
- HUMIDITY:OPERATING, NON-CONDENSING, 5% TO 95%
- VIBRATION:RANDOM OPERATING 2.4 GRMS/MAX. 3 AXES 50~500Hz 10 MINUTES/AXIS
- SHOCK:OPERATING HALF SINE 20 GPK/MAX. 3 AXES 10mS 6 SHOCKS TOTAL
|
| GENERAL SPECIFICATION: |
- TURN-ON TIME: 3SEC MAX AT FULL LOAD @ 115VAC
- HOLD-UP TIME: 16MS TYPI8CAL AT FULL LOAD @ 115VAC
- MTBF DEMOSTRATED: > 100,000 HOURS AT FULL LOAD AND 25 DEGREE AMBIENT CONDITIONAL
|
| ELECTROMAGNETIC COMPATIBILITY SPECIFICATIONS: |
- EMI CONDUCTED/RADIATED: FCC & CISPR CLASS B
- DESIGNED TO MEET EN61000-3-3,-4-2,-3,-4,-5,-6,-8,-11
|
| CONNECTOR TYPE & PIN ASSIGNMENTS |
|
|