Switching Mode Power Supply
LTE 45FSD SERIES 45W DUAL OUTPUT SWITCHING POWER SUPPLY

INPUT / OUTPUT SPECIFICATION
  • VOLTAGE: 100-240 VAC, Universal
  • FREQUENCY: 47-63
  • CURRENT: 1.5 ARMS. MAX @115 Vac 90W LOAD
  • INRUSH SURGE CURRENT: 30A TYPICAL, COLD START@25 Degree, 115Vac
  • OUTPUT WATTAGE: 26.4Watts ~65Watts MAX (Convection Rating)
  • LIND REGULATION: +/- 0.5 % Typical
  • LOAD REGULTION: Main Outputs +/- 5%, Aux Outputs +/- 10% Typical (Note1)
  • NOISE & RIPPLE: 1 % Typical At Full Load (Note2)
  • OVERLOAD / VOLTAGE PROTECTION: TYPICALLY 115~200% CONTINUOUS HICCUP MODE
  • SHORT CIRCUIT PROTECTION: CONTINUOUS HICCUP MODE
  • OVERSHOOT/UNDERSHOOT: 5% MAX, @ Turn-On / Turn-Off



Note: 1. LOAD REGULATION TESTED AT 0 ~100% OIF MAX LOAD
2. PEAK-TO-PEAK FOR 26.4W~65W (CONVECTION RATING) @90VAC MIN. ; MEASUREMENTS WITH A 20MHz BANDWIDTH AND TERMINATED WITH A 10uF ELECTROLYTIC CAP. IN PARALLEL WITH A 0.1uF CERAMIC CAP.

ENVIRONMENTAL:
  • OPERATING TEMPERATURE:0°C TO 50°C AMBIENT, DERATED EACH OUTPUT AT 2.5% PER °C FROM 50°C TO 70°C
  • STORAGE TEMPERATURE:-40°C TO 85°C
  • HUMIDITY:OPERATING, NON-CONDENSING, 5% TO 95%
  • VIBRATION:RANDOM OPERATING 2.4 GRMS/MAX. 3 AXES 50~500Hz 10 MINUTES/AXIS
  • SHOCK:OPERATING HALF SINE 20 GPK/MAX. 3 AXES 10mS 6 SHOCKS TOTAL

GENERAL SPECIFICATION:
  • TURN-ON TIME: 3SEC MAX AT FULL LOAD @ 115VAC
  • HOLD-UP TIME: 16MS TYPI8CAL AT FULL LOAD @ 115VAC
  • MTBF DEMOSTRATED: > 100,000 HOURS AT FULL LOAD AND 25 DEGREE AMBIENT CONDITIONAL

ELECTROMAGNETIC COMPATIBILITY SPECIFICATIONS:
  • EMI CONDUCTED/RADIATED: FCC & CISPR CLASS B
  • DESIGNED TO MEET EN61000-3-3,-4-2,-3,-4,-5,-6,-8,-11

CONNECTOR TYPE & PIN ASSIGNMENTS